Home    about us     products    resources    feedback    Literature    Training     contact us    FAQ     Terms & Conditions

 
  

The following tables list attenuation and near-end crosstalk (NEXT) specifications from ANSI/TIA/EIA-568A for Category 3, Category 5 and 6 unshielded twisted pair (UTP) cables.

TABLE 1: HORIZONTAL UTP CABLE ATTENUATION dB/100M (dB/1000 FT)

FREQUENCY
(MHZ)
CATEGORY
3
CATEGORY
5e
CATEGORY
6
0.772 2.2 (6.7) 1.8 (5.5) 1.8 (5.5)
1.0 2.6 (7.9) 2.0 (6.1) 2.0 (6.1)
4.0 5.6 (17.1) 4.1 (12.5) 3.8 (11.6)
8.0 8.5 (25.9) 5.8 (17.7) 5.3 (16.2)
10.0 9.7 (29.6) 6.5 (19.8) 6.0 (18.3)
16.0 13.1 (39.9) 8.2 (25.0) 7.6 (23.2)
20.0 - 9.3 (28.4) 8.5 (25.9)
25.0 - 10.4 (31.7) 9.5 (29.0)
31.25 - 11.7 (35.7) 10.7 (32.6)
62.5 - 17.0 (51.8) 15.4 (47.0)
100.0 - 22.0 (67.1) 19.8 (60.4)
200.0 - - 29.0 (88.4)
250.0 - - 32.8 (100.0)

TABLE 2: HORIZONTAL UTP CABLE NEXT LOSS, dB (WORST PAIR COMBINATION) 100M (328 FT)

FREQUENCY
(MHZ)
CATEGORY
3
CATEGORY
5e
CATEGORY
6
0.772 43 67 76
1.0 41 65 274
4.0 32 56 65
8.0 27 52 61
10.0 26 50 59
16.0 23 47 56
20.0 - 45 55
25.0 - 44 53
31.25 - 42 52
62.5 - 38 47
100.0 - 35 44
200.0 - - 40
250.0 - - 38